Products

RCIN3 control box

You have selected the following reference:

  • RCIN3 Control box
  • Control box with frequency converter.

    The RCVF4 control box has been designed to provide a solution to the automation of industrial doors.

    This device meets all the requirements in its mode of operation, as well as allows the interconnection of all the auxiliary devices needed for the correct operation of the door.

  • Image
  • Electrical surges
  • If an electrical surge occurs, the thermal magneto will act cutting off the power supply. A cut can also occur due to overheating of the motor through the thermal probe.

    Another cause of operation interruption may be due to an earth fault, in this case check the motor for any malfunction.

  • Downloads
  • Technical information
  • Power supply voltage 230V/400V triphasic
    Power absorbed at full load 2500W
    Motor output 3 phases at 230V/400V
    Low voltage auxiliary power output 24V-DC not filtered
    Maximum low voltage auxiliary power supply 300mA
    Electro-brake power output 220V/102V DC not filtered
    Plastic box with insulation cable gland IP55
    Motor power cable (the motor cable is shielded with earth connection) 4/9/12 meters long
    Relay output 1 voltage-free changeover contact (Maximum relay 1 switching capacity) 5A to 230V
    Relay output 2 changeover contact free of voltage (maximum relay 2 switching capacity) 5A to 230 V
    Closed contact input emergency stop mushroom Terminals st1 Y st2
    Stop pushbutton closed contact input Terminals ps1 y ps2
    Open contact input opening button + alternative Terminals pa1 y pa2
    Open contact input close button* Terminals pc1 y pc2
    Closed contact input or pnp photocell Terminals ft1 y ft2
    Closed contact input or pnp impact safety band Terminals bs1 y bs2
    The IP55 test was carried out according to category 2 according to section 10.3 of the UNE-EN 61439-1:2012 standard.
    *Contact entry for partial opening selection.